For Customer Service, contact the place of purchase to arrange for replacement parts.
4. By measuring determine correct number of links
needed for proper hanging height. Use a pair of
pliers to open one link of the Chain (C2) then
remove the excess Chain (C2) and discard it.
5. Use one chain connector (E2) to attach one end
of the chain to the Top loop (D2) and close the
chain connector.
6. Feed the fixture wires through the Chain (every
three links) and pull the wires until taut.
7. Slip Canopy loop collar (B2) over the chain, then
do the same with the canopy (F2).
8. When ready to complete the installation Use the
other chain connector and attach the other end of
the chain to the canopy loop (A2) and close the
chain connector.
9. Make sure the weight of the chandelier is
supported b
y
the chain-not the electrical wire.
* You may now install the fixture.
Fig 2
PARTS & ASSEMBLY SHEET
Fixture Name: Grace 1264-3P PW / RBZ
NOTE: Finish installing the glass after the fixture is hung.
10. Thread the Nipple (F) into the Socket assembly (E),
lock into position by the tightening hex nut.
11. Install the light bulbs in accordance with the fixture’s
specifications.
12. Slide the Spacer (H), Glass shade (G), Rubber
washer (I), Metal washer (J) over the Nipple (F) secure
them by the Hex Nut (K).
13. Slide the Bottom Cap (L) over the Nipple (F), screw
the Finial (M) onto the Nipple (F) until tight.
(DO NOT EXCEED THE MAXIMUM WATTAGE RATING)
.
Fig 3
B2
A2
C2
E2
D2
E2
A
B
C
D
E
F
G
H
I
J
K
L
M